Ratings 36 votes

?
Community ratings from NukeWorker members. Vote to share your experience working at this facility. Results show the breakdown of Above Average, Average, and Below Average ratings.

Capacity Factor (365-Day)

96%
Current
99.9%
365-Day Avg
#12
of 94 plants
Min: 90% Max: 100% 0 days <80%

Scram History

No scram events recorded since 2011.

Performance Charts

Outage Duration Trend

?
Scheduled refueling outage durations over time. Green bars are below average, yellow near average, red above. Dashed line shows the plant's historical average. Shorter outages mean better execution.

Power History (12-Month)

?
Daily power output as a percentage of rated capacity over the past 365 days. Green segments indicate full power (90%+), yellow shows reduced output, and red indicates significant power reductions or shutdowns.

Outage Timeline

?
Visual timeline of all recorded outages. Blue bars are scheduled refueling outages, red bars are forced/unplanned outages. Width represents outage duration. Hover for details.

Facility Statistics

Lifecycle & Tenure
Operating Age: 37.5 Yrs
Build Time: 12.8 Yrs
Lic. Remaining: 21.7 Yrs
Production & Power
Lifetime CF: 94.8%
Efficiency: 31.7%
Generated: 261.2 TWh
Reliability & Outages
Record Run: 549 Days
Refuelings: 18

Ownership & Construction

Owner/Operator: Constellation Energy
Architect Engineer: S&L
Constructor: CWE

Technical Specs

Reactor Type: PWR
Containment: PWR-DRYAMB
NSS Supplier: WEST 4LP
Thermal Power: 3645 MWt
Net Capacity: 1154 MWe
Efficiency: 31.7%
Status: Operating

Licensing

Docket #: 05000457
License #: NPF-77
License Type: OL-FP
Const. Permit: 1975-12-31
Operating Lic: 1988-05-20
Commercial Op: 1988-10-17
License Renewed: 2016-01-27
License Exp: 2047-12-18

Facility Map

41.2434, -88.2297

Location & Contact

Address:
35100 South Route 53
Braceville, IL 60407, USA
Get Directions
Phone: (815) 417-2000

Breaker-to-Breaker Runs 10 runs

?
Breaker-to-breaker runs measure continuous operation between refueling outages (470+ days). An active streak means the unit has been running continuously since the last refueling. Longer runs indicate better reliability.
524
Active Streak (days)
Since 2024-10-26
548
Best Run (days)
2015-10-24 → 2017-04-24
524
Avg Run (days)
All Runs
2024-10-26 Active 524 days
2023-05-14 2024-10-07 512 days
2021-11-06 2023-04-24 534 days
2020-05-07 2021-10-18 529 days
2018-11-02 2020-04-20 535 days
2017-05-21 2018-10-08 505 days
2015-10-24 2017-04-24 548 days
2014-05-23 2015-10-05 500 days
2011-05-13 2012-10-15 521 days
2005-05-05 2006-10-16 529 days