Nine Mile Point 2 - Plant Information & Status

Technical specifications, contact data, ratings, and licensing history for the Nine Mile Point facility.

Current Reactor Status

?
Current power output from NRC daily reactor status reports. Shows the most recent power level as a percentage of rated capacity, along with a 14-day power history.

Ratings 31 votes

?
Community ratings from NukeWorker members. Vote to share your experience working at this facility. Results show the breakdown of Above Average, Average, and Below Average ratings.

Capacity Factor (365-Day)

35%
Current
91.4%
365-Day Avg
#74
of 94 plants
Min: 0% Max: 100% 32 days <80%

Scram History 13 events since 2011

13
Total
7
Automatic
6
Manual
8.8
Avg Recovery (days)
Recent Events
2024-09-22 Auto AUTOMATIC REACTOR SCRAM DUE TURBINE TRIP The following infor...
2024-03-02 Auto AUTOMATIC REACTOR SCRAM DUE TO MAIN TURBINE TRIP ON LOW COND...
2023-09-01 Auto AUTOMATIC REACTOR SCRAM DUE TO FEEDWATER TRANSIENT The follo...
2022-04-04 Auto EN Revision Imported Date: 4/15/2022 EN Revision Text: SCRAM...
2020-03-03 Manual MANUAL SCRAM IN THE TURBINE CONTROL SYSTEM "At 1205 EST, on ...
2018-08-26 Auto AUTOMATIC SCRAM DUE TO A GENERATOR TRIP"At 0033 EDT Nine Mil...
2017-08-04 Auto AUTOMATIC REACTOR SCRAM DURING TESTING "At 2235 [EDT] Nine M...
2015-02-17 Manual MANUAL SCRAM DUE TO RAPIDLY RISING REACTOR WATER LEVEL "At 1...
+5 more events

Performance Charts

Outage Duration Trend

?
Scheduled refueling outage durations over time. Green bars are below average, yellow near average, red above. Dashed line shows the plant's historical average. Shorter outages mean better execution.

Power History (12-Month)

?
Daily power output as a percentage of rated capacity over the past 365 days. Green segments indicate full power (90%+), yellow shows reduced output, and red indicates significant power reductions or shutdowns.

Outage Timeline

?
Visual timeline of all recorded outages. Blue bars are scheduled refueling outages, red bars are forced/unplanned outages. Width represents outage duration. Hover for details.

Facility Statistics

Lifecycle & Tenure
Operating Age: 38.1 Yrs
Build Time: 13.7 Yrs
Lic. Remaining: 20.6 Yrs
Production & Power
Lifetime CF: 91.9%
Efficiency: 32.4%
Generated: 283.3 TWh
Reliability & Outages
Record Run: 717 Days
Refuelings: 14

Ownership & Construction

Owner/Operator: Constellation Energy
Architect Engineer: GE 5
Constructor: N/A

Technical Specs

Reactor Type: BWR
Containment: BWR-MARK 2
NSS Supplier: S&W S&W
Thermal Power: 3988 MWt
Net Capacity: 1292 MWe
Efficiency: 32.4%
Status: Operating

Licensing

Docket #: 05000410
License #: NPF-69
License Type: OL-FP
Const. Permit: 1974-06-24
Operating Lic: 1987-07-02
Commercial Op: 1988-03-11
License Renewed: 2006-10-31
License Exp: 2046-10-31

Facility Map

43.5206, -76.4078

Location & Contact

Address:
348 Lake Road
Scriba, NY 13126, USA
Get Directions
Phone: (301) 415-8200

Breaker-to-Breaker Runs 3 runs

?
Breaker-to-breaker runs measure continuous operation between refueling outages (470+ days). An active streak means the unit has been running continuously since the last refueling. Longer runs indicate better reliability.
702
Best Run (days)
2020-04-04 → 2022-03-07
594
Avg Run (days)
All Runs
2024-09-28 2026-03-09 527 days
2020-04-04 2022-03-07 702 days
2018-08-30 2020-03-05 553 days