NukeWorker Menu

Callaway - Plant Information & Status

Technical specifications, contact data, ratings, and licensing history for the Callaway facility.

Ratings 33 votes

?
Community ratings from NukeWorker members. Vote to share your experience working at this facility. Results show the breakdown of Above Average, Average, and Below Average ratings.

Capacity Factor (365-Day)

100%
Current
68.6%
365-Day Avg
#72
of 94 plants
Min: 0% Max: 100% 117 days <80%

Scram History 9 events since 2011

9
Total
9
Automatic
0
Manual
4.4
Avg Recovery (days)
Recent Events
2024-02-14 Auto AUTOMATIC TURBINE TRIP/REACTOR TRIP The following informatio...
2022-01-06 Auto EN Revision Imported Date: 2/7/2022 EN Revision Text: AUTOMA...
2020-12-23 Auto AUTOMATIC TURBINE AND REACTOR TRIP "At 1235 CST on December ...
2020-09-26 Auto AUTOMATIC REACTOR TRIP "At 0203 [CDT] on September 27, 2020 ...
2020-04-03 Auto AUTOMATIC REACTOR TRIP "At 0114 [CDT] on April 04, 2020 the ...
2019-05-16 Auto REACTOR TRIP DUE TO SOURCE RANGE HI FLUX SIGNAL "This is an ...
2015-08-10 Auto AUTOMATIC REACTOR TRIP AFTER AN OFFSITE ELECTRICAL FAULT "Re...
2014-12-02 Auto AUTOMATIC REACTOR TRIP DUE TO TURBINE TRIP "An unexpected ma...
+1 more events

Performance Charts

Outage Duration Trend

?
Scheduled refueling outage durations over time. Green bars are below average, yellow near average, red above. Dashed line shows the plant's historical average. Shorter outages mean better execution.

Power History (12-Month)

?
Daily power output as a percentage of rated capacity over the past 365 days. Green segments indicate full power (90%+), yellow shows reduced output, and red indicates significant power reductions or shutdowns.

Outage Timeline

?
Visual timeline of all recorded outages. Blue bars are scheduled refueling outages, red bars are forced/unplanned outages. Width represents outage duration. Hover for details.

Facility Statistics

Lifecycle & Tenure
Operating Age: 41.3 Yrs
Build Time: 8.7 Yrs
Lic. Remaining: 18.5 Yrs
Production & Power
Lifetime CF: 85.6%
Efficiency: 33.4%
Generated: 243.1 TWh
Reliability & Outages
Record Run: 528 Days
Refuelings: 18

Ownership & Construction

Owner/Operator: Ameren Missouri
Architect Engineer: BECH
Constructor: DANI

Technical Specs

Reactor Type: PWR
Containment: PWR-DRYAMB
NSS Supplier: WEST 4LP
Thermal Power: 3565 MWt
Net Capacity: 1190 MWe
Efficiency: 33.4%
Status: Operating

Licensing

Docket #: 05000483
License #: NPF-30
License Type: OL-FP
Const. Permit: 1976-04-16
Operating Lic: 1984-10-18
Commercial Op: 1984-12-19
License Renewed: 2015-03-06
License Exp: 2044-10-18

Facility Map

38.7594, -91.7855

Location & Contact

Address:
Junction Highway CC & O
Fulton, MO 65251, USA
Get Directions
Phone: (573) 676-8000

Breaker-to-Breaker Runs 4 runs

?
Breaker-to-breaker runs measure continuous operation between refueling outages (470+ days). An active streak means the unit has been running continuously since the last refueling. Longer runs indicate better reliability.
519
Best Run (days)
2007-05-11 → 2008-10-11
506
Avg Run (days)
All Runs
2016-05-11 2017-10-07 514 days
2011-11-26 2013-04-09 500 days
2010-06-13 2011-10-16 490 days
2007-05-11 2008-10-11 519 days