NukeWorker Menu

Catawba 1 - Plant Information & Status

Technical specifications, contact data, ratings, and licensing history for the Catawba facility.

Ratings 29 votes

?
Community ratings from NukeWorker members. Vote to share your experience working at this facility. Results show the breakdown of Above Average, Average, and Below Average ratings.

Capacity Factor (365-Day)

98%
Current
100%
365-Day Avg
#6
of 94 plants
Min: 98% Max: 100% 0 days <80%

Scram History 3 events since 2011

3
Total
3
Automatic
0
Manual
1
Avg Recovery (days)
Recent Events
2020-09-07 Auto AUTOMATIC REACTOR TRIP ON OVER POWER DELTA TEMPERATURE "At 0...
2020-02-11 Auto AUTOMATIC REACTOR SCRAM DUE TO MAIN TURBINE TRIP "At 1800 ES...
2012-04-03 Auto NOTICE OF UNUSUAL EVENT DUE TO DUAL UNIT LOSS OF OFFSITE POW...

Performance Charts

Outage Duration Trend

?
Scheduled refueling outage durations over time. Green bars are below average, yellow near average, red above. Dashed line shows the plant's historical average. Shorter outages mean better execution.

Power History (12-Month)

?
Daily power output as a percentage of rated capacity over the past 365 days. Green segments indicate full power (90%+), yellow shows reduced output, and red indicates significant power reductions or shutdowns.

Outage Timeline

?
Visual timeline of all recorded outages. Blue bars are scheduled refueling outages, red bars are forced/unplanned outages. Width represents outage duration. Hover for details.

Facility Statistics

Lifecycle & Tenure
Operating Age: 40.8 Yrs
Build Time: 9.9 Yrs
Lic. Remaining: 17.7 Yrs
Production & Power
Lifetime CF: 92.2%
Efficiency: 33.4%
Generated: 255.3 TWh
Reliability & Outages
Record Run: 544 Days
Refuelings: 18

Ownership & Construction

Owner/Operator: Duke Energy
Architect Engineer: DUKE
Constructor: DUKE

Technical Specs

Reactor Type: PWR
Containment: PWR-ICECND
NSS Supplier: WEST 4LP
Thermal Power: 3469 MWt
Net Capacity: 1160 MWe
Efficiency: 33.4%
Status: Operating

Licensing

Docket #: 05000413
License #: NPF-35
License Type: OL-FP
Const. Permit: 1975-08-07
Operating Lic: 1985-01-17
Commercial Op: 1985-06-29
License Renewed: 2003-12-05
License Exp: 2043-12-05

Facility Map

35.0528, -81.0717

Location & Contact

Address:
4800 Concord Road
York, SC 29745, USA
Get Directions
Phone: (803) 831-3000

Breaker-to-Breaker Runs 9 runs

?
Breaker-to-breaker runs measure continuous operation between refueling outages (470+ days). An active streak means the unit has been running continuously since the last refueling. Longer runs indicate better reliability.
542
Best Run (days)
2017-05-24 → 2018-11-17
507
Avg Run (days)
All Runs
2023-05-29 2024-10-01 491 days
2021-11-04 2023-04-19 531 days
2020-06-02 2021-10-17 502 days
2017-05-24 2018-11-17 542 days
2015-12-19 2017-04-29 497 days
2014-06-28 2015-11-21 511 days
2012-12-29 2014-05-06 493 days
2008-06-22 2009-11-07 503 days
2006-12-31 2008-05-04 490 days